Twin Cyclone Bus Vacuum System - Wilmington, DE

System Description:

Technical Information

Number of systems: One
Went into operation: June 1995
Air volume: 26,000 cfm
Horsepower: 50 HP
Noise level (on the fuel island): 88 dba (dampers open) 85 dba (dampers closed)
Collection containers per system: Two 3 cubic yard front loading trash containers
Compactor: None
Total busses cleaned daily: 125
Time needed to fill one container: 1 week (compacted trash)
Air filtration: Yes
Environment: Inside building with open bay doors on each end.
Discharge air location: Outside the building
Ceiling height: 23'
Service island width: 9'

System Report:

The "pull through" blower configuration is providing tremendous system performance--it allows the use of a more aero dynamically designed (efficient) blower. The collection efficiency has been flawless with one 3 cubic yard container being filled per day. 

The bellows horizontal cylinder replacement has been the only needed repair--a result of extending and retracting 125 times a day!

For a first hand report we urge you to contact the following:

Mr. Jeff Gropp
DART
1 South Monroe
Wilmington, DE 19801
(302) 577-3278 Ext. 3495

Please do not hesitate to contact us if you need more information about twin cyclone bus vacuum systems or if you have any questions.

Contact:

ROBERTSON AIR SYSTEMS
33381 Coral Reach, Dana Point, CA  92629
Phone:  (714) 420-1450   Fax:  (866) 906-1450
E-Mail: jim@robertsonairsystems.com
[Return to Projects]